Mastervolt inverters are designed to maximize annual yield under realistic conditions. In addition to perfect performance under normal conditions, you can expect the best possible energy capture – even in less favourable conditions.
The SunMaster ES is developed based on Mastervolt’s unique philosophy, the result of 20 years of solar experience. In addition to maximum efficiency, we focus on high yields in less than optimal conditions. As a result the SunMaster ES has various exclusive features:
Ease of use for both user and installer are key product features for Mastervolt. A clear graphic display with daily yield and a 30-day energy log provide the vital information you need about the operation of your PV system. The improved Optima Cooling system guarantees cool and efficient operation of the inverter and low noise, while the IP65 electronics housing provides optimum protection against moisture and dust. This makes the SunMaster ES suitable for both indoor and outdoor installation.
For a fast and flexible connection, the SunMaster ES comes with a waterproof plug and an integrated DC switch for optimum safety. Mounting is easy thanks to the robust, integrated handles and a mounting bracket. Another highly practical feature is the communication cassette, which can be partly taken out from the inverter.
The SunMaster ES works with any type of solar panel, including the latest thin film technologies*. The high input voltage and extensive operating range simplify the system design and reduce losses, while the reliable RS485 interface allows the inverter to be combined with a wide range of monitoring products. The inverter is also equipped with an Ethernet connection for network integration.
* Certain types of thin film panels require functional earthing. If such cases Mastervolt recommends its SunMaster XS inverters with HF transformer.
Depending on local regulations, utilities may require provision of reactive power. The SunMaster ES models are fully prepared for the German low voltage directive VDE-AR-4105. This feature will be activated when the corresponding country is selected during commissioning.
Product code: 131505000
SunMaster ES series
Solar Image Brochure (general)
solar Monitoring
consumer leaflet domestic market
RD1699/2011
Factory Inspection Certificate
VDE4105 Konformität und F2,F3,F4,G2,G3
AS4777 Certificate
Certificat de conformité VDE 0126
G59/2 certificate
Dichiarione di conformità CEI 0-21
Dichiarione di conformità CEI 0-21 V1
C10/11 : 2012-06 conformity
Conformita` A70 MT NO SPI > 6 kW
Manual SunMaster ES 3.6TL, ES4.6TL, ES5....
Sunmaster ES
installer settings
Mastervolt Produktportfolio Übersicht
Use of external RCD
CEI 0-21 information bulletin
| General specifications | ||
| Operating temperature |
-25 °C to 60 °C; derating power > 45 °C |
|
| Enclosure | coated aluminium |
|
| Protection degree | IP65 for outdoor application |
|
| Relative humidity | 4-100% non condensing |
|
| Safety class | class I |
|
| Inverter technology | transformerless |
|
| Cooling | passive + fan |
|
| Sound level (typ.) | < 40 dB(A) |
|
| Dimensions, hxwxd |
460x550x195 mm |
|
| Weight |
21 kg |
|
| Product warranty | 5 years |
|
| Solar input (DC) specifications | ||
| PV power range | 4300-6500 Wp |
|
| Start-up power | 10 W |
|
| Operating voltage range | 250-900 V |
|
| MPP voltage range at nom. power | 305-720 V |
|
| Nom. voltage | 670 V |
|
| Max. voltage | 900 V |
|
| Number of inputs | 1 MPP tracker and 2 sets MultiContact MC4 connectors |
|
| Efficiency MPP trackers (static/dynamic) | 99.9 % / 99.8 % |
|
| Max. input current | 1x 17 A |
|
| DC protection | surge arresters class III according to IEC 61643-1 |
|
| Grid output (AC) specifications | ||
| Grid voltage | 230 V +15%/-20% |
|
| Nom. output power | 5000 VA |
|
| Max. output power | 5000 VA / 5250 VA max. for Italy, the Netherlands, United Kingdom and France. For Germany max. 4600 VA |
|
| Max. output current | 24 A |
|
| Frequency | 50/60 Hz |
|
| Power factor | > 0.99 |
|
| Reactive power control | 0.90 inductive / 0.90 capacitive |
|
| DC current injection | < 20 mA |
|
| RCD | type B integrated |
|
| Low Voltage Ride Through (LVRT) | integrated |
|
| Standby power | < 1 W |
|
| EU efficiency | 97.0 % |
|
| Max. efficiency | 97.5 % |
|
| AC connection | Amphenol IP67 connector, suitable for 4-6 mm² cables |
|
| Regulations & directives | ||
| CE conformity | yes |
|
| German low voltage directive VDE AR-N-4105 | in conformity; max. one ES inverter per phase |
|
| Nat. grid requirements | VDE0126-1-1; CEI-021; RD1663; G83/1-1; G59/2; Synergrid C10/11 |
|
| Communication & monitoring | ||
| Display | LCD display with 4 buttons |
|
| Diagnostics | 30 days datalogger |
|
| Communication | 2x RS485 connections / Ethernet connection |
|
View product »
View product »
View product »
View product »
View product »
View product »
View product »
View product »